washer for vaporiser plant

practical conditions

In order to clean a vaporiser plant, an acid- / prine- washer had to be constructed. The narrow room conditions were a special difficulty.

function specifications:

The condensate is collected in an upper collecting vessel, as soon as the vessel is filled, the excessive water flows into the sewerage.

Whenever the vaporiser needs to be flushed, the condensate is discharged into the mixing vessel at first and then either acid or brine is added. Which medium and which pH-value is made up depends on the level of contamination of the vaporiser and the evaporated medium respectively.

As a result of the narrow room conditions a very compact unit had to be built, at the same time diverse safety specifications had to be observed, because highly concentrated acids and brines were used.

flow sheet small

Click here or the flow sheet for an enlarged view!

back to 'referenes process water'

All in all:

Leiblein purification of effluents - an optimal solution!


For more informations please contact us:

Leiblein GmbH · Adolf-Seeber-Str. 2 · 74736 Hardheim · Germany · Phone: +49 (0) 6283 - 2220 0
Fax: +49 (0) 6283 - 2220 50
E-Mail: leiblein@leiblein.com
Homepage: http://www.leiblein.com
process water
coolant technology
filtration technology
references
second-hand machinery
art gallery