effluent precleaning from a train washing plant

practical conditions

The drain water from a train washing plant should be treated before the discharge into the channel. Therefor a diaphragm unit should be used. To reach better operating lifes of the diaphragms a precleaning plant for the drain water should be installed.

function specifications:

At first the drain water is filtrated thriugh an inclinded filter, the filtrate is collected in a filtate tank and the sludge is discharged.

A coalescence separator removes the unattached oils.

Finally the water flows into a reaction vessel to sediment the dissolved materials.

The final treatment happens through ultrafiltration.

flow sheet small

Click here or the flow sheet for an enlarged view!

back to 'referenes coolant technology'

All in all:

Leiblein purification of effluents - an optimal solution!